Tel: +86-533-8409980
Home > News > Content

Non-Applicability Of Enamel Reactor

Zibo Taiji Industrial Enamel Co.,Ltd | Updated: May 24, 2017

1. In order to ensure the normal service life of the enamel reactor, the enamel reaction kettle is not suitable for chemical processes such as reaction, polymerization, storage and heat transfer of the following medium or material.

2. Any concentration and temperature of hydrofluoric acid and fluorine-containing media or materials, the concentration is greater than 30%, the temperature is greater than 180 °c phosphoric acid medium or materials, ph value is greater than 12 and the temperature is higher than 80 °c alkaline medium or materials.

3. The reaction process of acid and alkali materials alternately.

4. Enamel reaction kettle In the temperature play changes, the resulting too much stress will lead to the destruction of porcelain and equipment, so in the use of the process should be heated or cooled, to prevent the accumulation of cold poly heat.